滅火器是壓力容器,屬于歐盟CE認證中的PED指令2014/68/EU,該指令是針對壓力設備的安全指令,凡是設計壓力超過0.5bar的設備,無論其壓力、容積為何,均須符合PED指令的規定。
滅火器是一種可攜式滅火工具。滅火器內放置化學物品,用以救滅火災。
滅火器是常見的防火設施之一,存放在公眾場所或可能發生火災的地方,不同種類的滅火器內裝填的成分不一樣,是專為不同的火災起因而設的,我們使用時必須注意,以免產生反效果及引起生命危險。
滅火器是壓力容器,屬于歐盟CE認證中的PED指令,該指令是針對壓力設備的安全指令,凡是設計壓力超過0.5bar的設備,無論其壓力、容積為何,均須符合PED指令的規定。
1.干粉滅火器CE認證EN 615的相關規定:EN 615-2009 防火。滅火介質。滅火粉規范(D級粉除外)
2.推車式滅火器需要符合EN 1866,該標準是針對移動式滅火器的安全規定。
3.EN 3-7:滅火器的性能測試標準;
EN 3-8 :粉和泡沫滅火器CE認證;
EN 3-9:二氧化碳滅火器CE認證;
4.滅火器CE認證所執行的現行有效標準如下,
EN 3-7-2004+A1-2007 Portable fire extinguishers-Part 7: Characteristics, performance requirements and test methods
EN 3-7-2004+A1-2007 便攜式滅火器。特性、性能要求和試驗方法
EN 3-8:2006 Portable fire extinguishers - Part 8: Additional requirements to EN 3-7 for the construcion,resistance to pressure and mechanical tests foiextinguishers with a maximum allowable pressure equal to or lower than 30 bar
EN 3-8:2006便攜式滅火器。第8部分:EN3-7MAX大允許壓力≤:30bar滅火器結構的耐壓和機械試驗的附加要求
EN 3-9:2007 Portable fire extinguishers - Part 9: Additional requirements to EN 3-7 for pressure of c02 extinguishers
EN 3-9-2007 手提式滅火器-第9部分:附加要求EN 3-7二氧化碳滅火器耐壓
EN 3-10:2009 Portable fire extinguishers. Provisions for evaluating the conformity of a portable fire extinguisher to EN 3-7
EN 3-10:2009 手提式滅火器-第10部分: 評估便攜式滅火器符合EN 3-7的規定
BS EN 615:2009 Fire protection. fire extinguishing media. Specifications for powders (other than class D powders)EN 615-2009 防火。滅火介質。滅火粉規范(D級粉除外)
5.另外二氧化碳滅火器的鋼瓶還需要滿足IS0 9809或者EN 1964的要求。鋁瓶滅火器需要滿足BS 5045的法規要求。
BS EN IS0 9809-1:2010. Gas cylinders. Refilable seamless steel gas cylinders. Design, construcion and testing. Quenched and tempered steel cylinderswith tensile strength less than 1100 MPa
BS EN IS0 9809-2:2010. Gas cylinders. Refilable seamless steel gas cylinders. Design, construction and testing. Quenched and tempered steel cylinderswith tensile strength greater than or equal to 1100 MPa
BS EN IS0 9809-3:2010, Gas cvinders, Refllable seamless steel gas cylinders, Design, construction and testing. Normalized steel cyinders
BS IS0 9809-4:2014. Gas cylinders. Refllable seamless steel gas cylinders. Design, construction and testing. Stainless steel cylinders with an km value ofless than 1 100 MPa
BS EN 1964-3:2000. Transportable gas cylinders. Specification for the design and construction of refllable transportable seamless steel gas cylinders ofwater capacities from 0,5 litre up to and including 150 itres. Cyinders made of seamless stainless steel with an $iR$dm value of less than 1 100 Mpa
BS 5045-6: 1987. Transportable gas containers. Specification for seamless containers of less than 0.5 litre water capacity
BS 5045-7:2000.Transportable gas containers. Specification for seamless steelI gas containers of water capacity 0.5 L up to 15 L for special portableapplications
6.滅火器的選擇
在選擇滅火器時應符合下列規定:
6.1、撲救A類火災應選用水型、泡沫、干粉、鹵代烷等滅火器;
6.2、撲救B類火災應選用干粉、泡沫、鹵代烷、二氧化碳等,撲救水溶性B類火災不得選用化學泡沫滅火器;
6.3、撲救C類火災應選用干粉、鹵代烷、二氧化碳型滅火器;
6.4、撲救帶電設備火災應選用鹵代烷、二氧化碳、干粉滅火器;
6.5、撲救A、B、C、類和帶電設備火災應選用干粉、鹵代烷滅火器;
6.6、撲救D類火災應選用專用干粉滅火器。
7.標識
標識一般用印刷的不干膠貼在筒體的外表,標識的檢查主要檢查標識的內容,是否正確完整。標識的檢查內容應該有:
滅火器名稱、型號、
滅火級別、使用溫度范圍、驅動氣體數量和名稱、
制造廠商名稱、滅火器的使用方法等,
認證檢驗機構的代碼,CE標識。